Part Number Hot Search : 
1N652 222M35 74HC404 TC100 PX0597 Z23C1 BA8205 TK112
Product Description
Full Text Search
 

To Download XE900S-500 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 XE900S-500
June 2005
XE900S-500 Smart Spread Spectrum Transceiver
Description The XE900S-500 combines a spread spectrum transceiver and micro-controller in a single, easy-touse, FCC Part 15 Registered module. The embedded communications controller manages the Frequency Hopping Spread Spectrum (FHSS) link and the host system interface. The XE900S-500 supports two unique features to simplify wireless networking. Count-OffTM allows the network master to quickly retrieve the status of 125 remote nodes with a single broadcast command. SensorOnAirTM eliminates the need for an application controller by utilizing the communications controller to directly manage analog inputs and digital control lines. Xecom also offers a low power spread spectrum model, the XE900SL10, for applications that require less range. The XE900SL10 has an obstructed range of 300 feet but is smaller, costs less and uses significantly less power. Features * Small Size: 1.295" by 1.410" by 0.255" * Serial Control and Configuration of the Wireless Link. * Supports a 254 node point-to-multipoint network * Programmable Transmit Power Output 100 to 500 mW. * Typical Receiver Sensitivity -100 dBm * Obstructed signal range to 1000 feet; * Wireless Data Rate 76.8K bps, half-duplex * Low power Consumption XE900S-500: 1000 mA @ 3.3 Volts; when transmitting at 500 mW output power; less than 1 mA of current flows in Sleep Mode or Power-Down modes * SensorOnAirTM (patent pending) allows direct connection of sensors to the Smart Transceiver * Count-OffTM (patent pending) allows the host node to download the status of all nodes in under 10 seconds. * Operating Temperature Range of -40 to +85 C * FCC Part 15 Registered
XE900S-500 Block Diagram
Antenna
SAW FILTER
ROM
Serial I/F
MUX
TRANSCEIVER
COMM. CONTROLLER
Analog Inputs Digital I/O
AMP
SAW FILTER
XECOM
(1)
XE900S-500
XE900S-500 MECHANICAL SPECIFICATIONS
F
E
H
Top View G B I
C A D H
Dimension A B C D E F G H I
Description Module Width Module Length Module Thickness Minimum Lead Length Antenna Width Edge to Antenna Pin to Pin Spacing Edge to End of Pin Row Pin Row Length
Inches 1.295 1.410 0.255 0.125 0.134 0.995 0.100 0.155 1.100
MM 32.89 35.81 6.48 3.18 3.40 25.27 2.54 3.94 27.94
XECOM
(2)
XE900S-500
Layout PCB for XE900S-500 and XE900SL10
Despite the fact that the XE900S-500 is substantially larger module than the XE900SL10, a common PCB layout can be used to support both products. This makes it easy to accommodate applications which include nodes with both long range and short range requirements. The XE900S-500 and XE900SL10 can share board layout because of common pin assignments. Pins 1 through 8 of the XE900SL10 are equivalent to Pins 3 through 10 on the XE900S-500; they have the same functions and are placed in the same sequence. Pin 9 on the XE900SL10 is an unused pin and therefore does not conflict with the ADC1 signal assigned to Pin 11 of the XE900S-500. The XE900SL10 requires a separate pin row for Pins 10 through 14. These pins will be hidden under the XE900S500 module when the larger module is installed. The XE900SL10 also includes one unique signal, Reset. Reset is an active high signal that can be left unconnected if no external reset is desired. The figure below shows the overlapping layout that supports both modules. The XE900S-500 outline and pins are shown in green. XE900SL10 pins and outline are shown in red.
XE900S-500/XE900SL10 Overlay
Gnd Vcc /TXD /RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 ADC1/NC ADC0
1 2 3/1 4/2 5/3 6/4 7/5 8/6 9/7 10/8 11/9 12
XE900S-500 XE900SL10
14 13 12 11 10
Reset ADC0 ADC1 Vcc Gnd
XECOM
(3)
XE900S-500
Using the XE900S-500 Power Saving Modes
The XE900S-500 includes three low power operating modes (Sleep, Power-Down and RF Monitor) to allow the host application to make maximum use of the available power. The #P command determines how the transceiver will operate when not being asked to transmit or receive an RF signal. Below are descriptions of all of the XE900S-500 operating modes. IDLE: In Idle Mode all circuits within the XE900S-500 are powered and available for immediate action. This includes the RF receiver which actively monitors the air for an incoming communications request. Current draw in Idle Mode is typically 23 milliamps. SLEEP: In Sleep Mode all circuits within the XE900S-500 are powered-down to reduce consumption. The XE900S-500 will not accept commands or respond to incoming RF communications requests. Any input on the TXD line will wake the transceiver and return it either the Idle or Power-Down Mode which ever mode it was last in before being put into Sleep Mode. Current draw in Sleep Mode is less than 100 microamps. Power-Down: In Power-Down Mode all RF circuitry is shut down but the communications controller remains active to accept AT commands. In this mode the XE900S-500 cannot respond to incoming RF communications requests. If a transmit RF or Receive RF command is received, the XE900S-500 can activate the RF section in under 200 microseconds. Current draw in Power-Down Mode is less than 800 microamps. RF Monitor Mode: The XE900S-500 includes 4 RF monitor modes. In each of these RF Monitor modes the transceiver sits in power down mode for a prescribed period of time. The transceiver then wakes up, turns on its receiver and checks for incoming messages. If no messages are received the transceiver returns to power down mode after about 200 milliseconds. If a carrier is detected, the transceiver completes the transaction before returning to power down mode. Intervals of 2 seconds (#P3, 4 seconds (#P4), 8 seconds (#P5) and 16 seconds (#P6) can be selected. RF Receive Mode: In RF Receive Mode the XE900S-500 is actively receiving an incoming 900 MHz data signal. Current draw in RF Receive Mode is typically 35 milliamps. RF Transmit Mode: In RF Transmit Mode the XE900-500 is actively transmitting a 900 MHz data signal. Current draw in Transmit mode is no more than 1000 milliamps with the transmit output power set to maximum, 500 milliwatts. AT Command Control The power saving modes are controlled by the AT#Pn command, see below. AT#P0 - Sets the transceiver to Idle mode. AT#P1 - Sets the transceiver to Sleep Mode. AT#P2 - Sets the transceiver for Power-Down Mode. AT#P3 - RF Monitor Mode (2 second interval) AT#P4 - RF Monitor Mode (4 second interval) AT#P5 - RF Monitor Mode (8 second interval) AT#P6 - RF Monitor Mode (16 second interval)
XECOM
(4)
XE900S-500
XE900S-500 PIN CONFIGURATION
GND VCC /TXD /RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 ADC1 ADC0 1 2 3 4 5 6 7 8 9 10 11 12
XE900S-500 Top View
SIGNAL
Ground VCC /TXD /RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 ADC1
PINS
1 2 3 4 5 6 7 8 9 10 11
DESCRIPTION
Common voltage reference for the XE900S-500. 3.3 Volt power for the XE900S-500. Transmit Data is the data input to the XE900S-500 Received Data is the data output from the XE900S-500. Clear to Send provides hardware flow control from the XE900S-500. The XE900S-500 drives /CTS high to signal the host to temporarily stop the flow of data on the /TXD. Request to Send provides hardware flow control from the host system. The host system drives /RTS high to signal the XE900S-500 to temporarily stop the flow of data on /RXD. DIO3 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900S-500. DIO2 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900S-500. DIO1 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900S-500. DIO0 may be programmed as either a digital input or digital output. It connects directly to the communications controller in the XE900S-500. Analog Input 1 to the XE900S-500 communications controller. ADC1 connects to an internal 12-bit Analog to Digital Convertor. ADC0 may also be configured as a digital input if no analog inputs are required. Analog Input 0 to the XE900S-500 communications controller. ADC0 connects to an internal 12-bit Analog to Digital Convertor. ADC0 may also be configured as a digital input if no analog inputs are required.
ADC0
12
XECOM
(5)
XE900S-500
ABSOLUTE MAXIMUM RATINGS
VCC Storage Temperature Operating Temperature Range 3.9 Volts -55O C to +125O C -40O C to +85O C
WARNING: Exceeding any of these ratings will void the warranty and may damage the device
XE900S-500 ELECTRICAL SPECIFICATIONS
Parameter
VCC ICC 35 23 2.2 1.1 0.6 0.3 0.8 0.10 Output Power: Wireless Receive Sensitivity Range thru Physical Obstructions Frequency Hopping Channels Frequency Band Antenna Output Impedance Voh V ol Vih Vil 2.25 0.75 2.25 0.75 902 50 100 -100 1000 50 928 MHz Ohms Volts Volts Volts Volts VCC =3.3 Volts VCC =3.3 Volts VCC =3.3 Volts VCC =3.3 Volts 500
Min
2.7
Typ
3.3
Max
3.6 1000
Units
Volts mA mA mA mA mA mA mA mA mA mW dBm feet
Comments
Transceiver power Transmit (500 mW output) Receive Mode Idle Mode Avg; 2-sec RF Monitor interval Avg; 4-sec RF Monitor interval Avg; 8-sec RF Monitor interval Avg; 16-sec RF Monitor interval Power-Down Mode Sleep Mode 50 Ohm Load
500 mW output
XECOM
(6)
XE900S-500
XE900S-500 TYPICAL CONNECTION DIAGRAM
3.3V Antenna
C1 C2 C3
C4 L1
C5 GND VCC /TXD
Host Serial I/F
/RXD /CTS /RTS DIO3 DIO2 DIO1 DIO0 ADC1 ADC0
Parts List for XE900S-500 Typical Connection Diagram
Reference Designation C1 C2, C4 C3, C5 L1 Antenna * Qty 1 2 2 1 1 Description Capacitor, Electrolytic, 100 ufd, 10 Volts Capacitor 0.1 ufd, 10 Volts Capacitor 47 pfd, 10 Volts Coilcraft 0603HC-7N5XJB 50 Ohm, 1/4 Wave;
* The Antenna connector on XE900S-500 models is a Male MMCX connector. An female MMCX to Female SMA adapter is needed for the antenna connection
XECOM
(7)
XE900S-500
XE900S-500 COMMUNICATIONS CONTROLLER
The XE900S-500 uses an internal micro-controller to control communications. This micro-controller manages the interface to the host system, determines when the communications link is available, and formats data for the RF communications. HOST INTERFACE The XE900S-500 has two primary interfaces to the system host; the serial interface and the direct sensor interface supported by the SensorOnAirTM feature. Management of both interfaces is the responsibility of the communications controller. RS232 Interface The XE900S-500 supports a 4-signal serial interface. For most applications the XE900S-500 will act as a DCE. Control and configuration of the XE900S-500 takes place through the serial interface using modem-like AT commands. The serial data rate is configurable from 1200 bits per second to 115.2K bits per second. The supported serial interface signals are listed below. /TXD - Transmit Data; the input to the XE900S-500 for AT commands and Data to be transmitted on the wireless network. /RXD - Received Data; the output from the XE900S-500 for received RF data and responses to AT commands. /RTS - Request to Send, provides the hardware flow control input to the XE900S-500. The DTE removes RTS to stop the XE900S-500 from sending more data on the RXD line. /CTS - Clear to Send, is the hardware flow control output from the XE900S-500. The XE900S-500 deactivates Clear to Send to advise then host to stop inputting data on the TXD lead. XE900S-500 AT Command Format AT commands issued to the XE900S-500 follow a strict format. Each command begins with the prefix AT and ends with a carriage return. The XE900S-500 communications controller accepts commands at data rates from 1200 to 115,200 bps. The default serial data rate is 9600 bps and can be changed using register S23. The communications controller uses the AT command prefix to automatically determine the parity of the incoming characters. Command Prefix - Each command, except the A/ command, begins with the AT prefix. The "A" and "T" may be either both upper case or both lower case but cannot be of different cases. The prefix identifies parity of the commands sent to the XE900S-500 by comparing the parity bits of the "A" and the "T" characters. Command Line - Commands may be strung together in a single command line of up to 30 characters. Commands in the command string are executed in the sequence they appear. Omitted Parameters - Most commands include a parameter which determines the function setting. When the command parameter is omitted from the command string, it is assumed to be a 0. Result Codes - A result code is normally issued after each action. Result codes may be provided as full words, one or two digit numeric codes, or may be disabled all together. Each result code ends with a carriage return when numeric result codes are chosen. When full word result codes are chosen, a Line Feed and Carriage Return precede and follow each result code. Disconnect Sequence - A three character sequence initiates a disconnect of the wireless link. The sequence "~~~" is assigned to disconnect the link. DIRECT CONNECTION OF SENSORS: SensorOnAirTM Sensors can be connected directly to the XE900S-500 without requiring an applications controller. In this SensorOnAirTM configuration the XE900S-500 communications controller controls the operation of the sensors. Sensor I/O Lines SensorOnAir controls the operation of 6 I/O lines to the XE900S-500. This includes 2 analog inputs, ADC0 and ADC1, and 4 digital I/O lines, DIO0, DIO1, DIO2, and DIO3. ADC0 and ADC1 are connected to a 12-bit analog to digital converter and use a 2.5 volt reference derived from VCC as their reference voltage. The digital I/O lines can be programmed to act as either inputs or outputs.
XECOM
(8)
XE900S-500
XE900S-500 COMMUNICATIONS CONTROLLER
Configuring the XE900S-500 for Sensor Operation All SensorOnAir control functions for the analog inputs and digital I/O's are performed by the communications controller within the XE900S-500. Modem-like AT commands loaded through the serial interface, program the functions of the analog and digital I/O lines. The AT commands used to program the SensorOnAir functions are then stored in the XE900S-500 Flash memory. This allows the XE900S-500 to be first programmed and then installed in the application. The communications controller uses the information stored in Flash memory to control the analog and digital I/O lines. SensorOnAir CommandsTM Below is a list of the AT commands used to program the direct control of sensors using the communications controller in the XE900S-500.
S107 Defines the function of the programmable I/O lines. The two analog input lines, ADC0 and ADC1, can also be defined as digital I/O lines if needed. The four programmable digital I/O lines, DIO0, DIO1, DIO2, and DIO3; can be set as either inputs or outputs. The value of this command is stored in flash memory within the XE900S-500.
WIRELESS COMMUNICATIONS The communications controller manges the RF Link. This includes the frequency hopping algorithm for spread spectrum operation; collision avoidance, node addressing, and packetizing data. The communications controller allows support for point-to-point, point-tomultipoint or multipoint networks. Carrier Sense Multiple Access (CSMA) To prevent collisions between network nodes the XE900S-500 uses a Carrier Sense Multiple Access protocol for each network transceiver. In normal communications all nodes, including the Master node in a point-toMultipoint network, listen for communications activity before initiating a session. If a wireless link already exists, the transceiver waits until that session is complete before initiating a wireless link. Data Packets All data presented by the system host is placed into packets by the XE900S-500 communications controller for transmission across the wireless link. These packets provide addressing and error correction for the wireless communications. The communications controllers place the data in packets only for the wireless link. The data is extracted from the packets before being sent out the serial interface. File Transfer Mode Xecom's XE900S-500 incorporates a File Transfer mode that uses a simplified networking protocol so that the maximum data transfer rate is achieved. In this mode the XE900S-500 does not automatically retransmit blocks containing errors. A CRC 16 checksum is calculated, transferred at the end of the file, and checked by the receiving unit. An "ERROR" message is displayed if the checksum calculated at the receive end does not match the checksum transmitted with the data. The File Transfer Mode is controlled by the AT#T command. The format of the command is AT#Txx; where xx is the destination address of the file. Following is a sample file transfer.
AT&IAn? - This command allows a local host to read the value of Analog Input "n." AT&IDn? - This command allows a local host to read the status of Digital I/O "n." AT&IDn=z - This command allows a local host equipment to set the condition of the local digital output "n." When z=0 the output is set to a logic low; when z=1 the output is set to a logic high. AT#IxxxAn? - This command allows the value of Analog Input "n" on node address "xxx" to be read remotely. AT#IxxxDn? - This command allows the status of Digital I/O "n" on node address "xxx" to be read remotely AT#IxxxDn=z - This command allows the condition of the local digital output "n" on node address "xxx" to be set remotely. When z=0 the output is set to a logic low; when z=1 the output is set to a logic high.
XECOM
(9)
XE900S-500
XE900S-500 COMMUNICATIONS CONTROLLER
Sample File Transfer
Transmitter TXD RXD AT#T01 : abc...z 3 sec pause in data Receiver TXD RXD FILE abc...z A718 OK or ERROR Description Initiate File Transfer Link Established File Data Checksum at End of File Transfer File Transfer Successful Error Detected in File Transfer
Notes: The above example shows that the file transfer is assumed to be completed if three seconds pass with no data being presented to the TXD input on the serial port. File Transfer Mode cannot be used to send binary data. Multipoint Network System designers using the XE900S-500 can create a point-to-multipoint network with up to 125 remote nodes. The master node is assigned address 1. The remote nodes are assigned address from 2 to 126. Xecom created Count-Off to insure efficient network operation. Count-Off allows the master node to poll the entire network in less than 10 seconds. The Count-Off creates a temporary time division multiplexing scheme which permits each node to report its status without the handshaking sequence normally required for a wireless data exchange. The Count-Off sequence is initiated by the AT#C command from the host system. The Master node broadcasts the Count-Off command to all network nodes. Upon receipt of the Count-Off broadcast each remote node initializes an internal timer. Then in sequence by address each node sends an 8-byte status message to the Master. The status message is programmed with the AT#E: or AT#E= command. Due to difficulties in synchronizing the spread spectrum signals, a node may sometimes miss the Count-Off command. The network administrator should poll any node that does not respond to the Count-Off request to insure the network integrity Using Count-Off network reporting will be completed in less than 10 seconds. Based on the status information the host can then elect to service any of the remote nodes.
COUNT-OFFTM SEQUENCE
Node 1 Node n Node 2 Node n Node 1 Node 2 Node n Node 1 Node 2 Node n Node 1 Node 2
Node 9 Master Node 8
Node 3
Node 9 Master
Node 3
Node 9 Master
Node 3
Node 9 Master
Node 3
Node 4
Node 8
Node 4
Node 8
Node 4
Node 8
Node 4
Node 7 Node 6
Node 5
Node 7 Node 6
Node 5
Node 7 Node 6
Node 5
Node 7 Node 6
Node 5
T0 - Master Broadcasts Count-Off Initiation
T1 - Node 1 Transmits 8-Byte Status
T2 - Node 2 Transmits 8-Byte Status
Tn - Node n Transmits 8-Byte Status Count-Off Complete
XECOM
(10)
XE900S-500
AT COMMANDS
An asterisk indicates the factory default A Dn En Answer Command - forces the smart transceiver respond to a summons from another wireless device. Initiate a Wireless Link - attempts to establish a connection with the transceiver at address n. Echo Characters - determines if the XE900S-500 will echo the characters received on its serial interface during command mode. n=0 Characters not Echoed n=1 Characters Echoed * In Identification - displays product identification code. n=0 Display Product Code n=1 Display Product Name n=2 Display Model Number n=3 Display Copyright n=4 Display Firmware Revision Qn Result Code Display - determines if result codes will be displayed. n=0 Display Result Codes * n=1 Do not Display Result Codes Sn= Set Value of Register Sn Sn? Vn Read Value of Register Sn Response Type - selects Full Word or Numeric responses n=0 Numeric Responses n=1 Full Word Responses * Zn Reset - executes a soft Reset n=0 Reset to Values Stored in User Profile 0 *. n=1 Reset to Values Stored in User Profile 1 &F Restore Factory Settings - returns all configuration commands and registers to their factory default values. #C #B &V &IDn? Read Local Digital Input "n" - This command allows the host equipment to read the status of the local digital inputs. n=0 Read input DIO0 n=1 Read input DIO1 n=2 Read input DIO2 n=3 Read input DIO3 n=4 Read input DIO4 (pin shared with ADC0) n=5 Read input DIO5 (pin shared with ADC1) &IDn=z Set Local Digital Output "n" - This command allows the host equipment to set the condition of the local digital outputs. When z=0 the output is set to a logic low; when z=1 the output is set to a logic high. n=0 Set output DIO0 n=1 Set output DIO1 n=2 Set output DIO2 n=3 Set output DIO3 &Kn Flow Control - selects the type of flow control to be used between the system host and the XE900S-500 n=0 Flow Control Disabled n=3 RTS/CTS, hardware Flow Control n=4 XON/XOFF, in-band Flow Control View Active Configuration - sends the active configuration data to the system host.
&Wn Store Current Configuration - loads the current XE900S-500 configuration into either User Profile 0 or User Profile 1. n=0 load configuration into User Profile 0 n=1 load configuration into User Profile 1 Wireless Broadcast Mode - initiates wireless broadcast mode for diagnostic purposes. Count-Off Request (ASCII) - Initiates a "count-off' sequence in the network with node status to be reported in ASCII format. Count-Off Response (ASCII) - Programs the nodes 8 byte response to a "count-off' request from the network hub in ASCII format. Count-Off Response (Hex) - Programs the nodes 8 byte response to a "count-off' request from the network hub in hexadecimal format.
&IAn? Read Local Analog Input "n" - This command allows the host equipment to read the values of the local analog inputs. n=0 Read input ADC0 n=1 Read input ADC1
#E:
#E=
XECOM
(11)
XE900S-500
AT COMMANDS
#IxxxAn? Read Analog Input "n" at Node Address xxx This command allows analog input values at any node to be read remotely. n=0 Read input ADC0 n=1 Read input ADC1 #IxxxDn? Read Digital Input "n" at Node Address xxx This command allows the status of the digital inputs at any node to be read remotely. n=0 Read input DIO0 n=1 Read input DIO1 n=2 Read input DIO2 n=3 Read input DIO3 n=4 Read input DIO4 (pin shared with ADC0) n=5 Read input DIO5 (pin shared with ADC1) #R #Pn #IxxxDn=z Set Digital Output "n" at Node Address xxx - This command allows the condition of the digital outputs to be modified remotely. When z=0 the output is set to a logic low; when z=1 the output is set to a logic high. n=0 Set output DIO0 n=1 Set output DIO1 n=2 Set output DIO2 n=3 Set output DIO3 Low Power Operation - Allows the XE900S-500 to operate in reduced power modes. n=0 Selects Normal Power Mode n=1 Places Transceiver in Sleep Mode; n=2 Places Transceiver in Power-Down Mode Receive Broadcast - Allows XE900S-500 to receive a broadcasted message and present it on the serial interface.
#Txx File Transfer - initiates a file transfer to the destination address xx.
XE900S-500 Responses
Numeric 0 1 2 3 4 6 7 8 9 Full Word OK CONNECT RF RING DISCONNECT ERROR NO CONNECTION BUSY SORRY WAIT FILE Description Successfully executed command line Wireless Connection Established Wireless Link Request Detected Lost Wireless Link Error in command line, or file transfer Failed to Establish Wireless Link Link Request Time Out has occurred No Response to Count-Off Request Wireless Link is not available File Transfer Mode
XECOM
(12)
XE900S-500
XE900S-500 Configuration Registers
S0 Answer Wireless Link Request: S0 determines if the XE900S-500 will automatically respond to a wireless link request. S0=0 S0=1 No Automatic response to link requests Automatically respond to link requests S23 Serial Interface Data Rate - S23 stores the serial interface data rate. Range 1-10 1 = Set serial data rate to 1200 BPS 2 = Set serial data rate to 2400 BPS 3 = Set serial data rate to 4800 BPS 4 = Set serial data rate to 9600 BPS* 5 = Set serial data rate to 14400 BPS S2 Wireless Disconnect Character - S2 sets the ASCII character to be used in the link disconnect sequence. The default character is the tilde "~". Range: 0-255 6 = Set serial data rate to 19200 BPS 7 = Set serial data rate to 28800 BPS 8 = Set serial data rate to 38400 BPS 9 = Set serial data rate to 57600 BPS 10 = Set serial data rate to 115200 BPS Default: 4 S39 Bit-mapped Register - S39 stores the value of the AT&K command. S104 Group ID Number - S104 sets the Group ID number for the XE900S-500. Up to "n" groups may be active in the same area. Only transceivers with the same Group ID number can communicate. Range: 0-255
S0=128 Enter Broadcast mode on power-up. The command must be stored in nonvolatile memory using the AT&W command.
Default: 126 S7 Link Set-up Timer - S7 sets the length of time in seconds that the transceiver will attempt to create a link with the destination node. Range: Default: 0-60 10
S10 Link Recovery Timer - S10 sets the length of time in seconds that the transceiver tries to recover a broken link. Range: Default: 0-60 10
Default: 0 S105 XE900S-500 ID Number - S105 sets the ID number for the XE900S-500. Each unit on the Base Access Network is required to have a unique ID number. Range: 1-254
S12 Disconnect Guard Timer - S12 sets the guard timer in milliseconds before and after the disconnect sequence. If any characters other than the disconnect sequence are received within the window defined by S12 the disconnect request will be ignored.. Range: 0-255
Default: 20 Units: Milliseconds
S14 Bit-mapped Register - S14 stores the values of the ATE, ATQ and ATV commands.
XECOM
(13)
XE900S-500
XE900S-500 Configuration Registers
S107 I/O Configuration - S107 is a bit-mapped register which defines the local programmable I/O lines. Bit 0 = 0 - ADC0 and ADC1 used as Programmable I/O = 1 - ADC0 and ADC1 defined for Analog use Bit 1 = reserved Bit 2 = 0 - DIO0 used as an output = 1 - DIO0 used as an input Bit 3 = 0 - DIO1 used as an output = 1 - DIO1 used as an input Bit 4 = 0 - DIO2 used as an output = 1 - DIO2 used as an input Bit 5 = 0 - DIO3 used as an output = 1 - DIO3 used as an input Bit 6 = 0 - DIO4 used as an output (Bit 0 = 0) = 1 - DIO4 used as an input Bit 7 = 0 - DIO5 used as an output (Bit 0 = 0) = 1 - DIO5 used as an input Default: 193 S108 Transmit Level Control - S108 sets the transmit level Range: 0-3 0 1 2 3 Default: 3 20 dBm 23 dBm 26 dBm 27 dBm
XECOM
(14)
XE900S-500
FCC PART 15 REGULATIONS
Mounting the XE900S-500 in Your Assembly The XE900S-500 must be mounted horizontally on your printed circuit board to maintain proper orientation of the transceiver. Standoffs should also be used on the side opposite the pin row to maintain clearance between the XE900S-500 and you printed circuit board. The XE900S-500 may not be co-located with any other antenna or transmitter. XE900S-500 Antenna The XE900S-500 is certified for compliance to FCC Part 15 rules only using the Xecom XE900A500, 1/4 wave monopole antenna. Use of any other antenna violates FCC Part 15 rules. FCC Part 15 Certification The XE900S-500 has been certified per FCC Part 15 rules for integration into OEM products without further testing or certification. This certification is your assurance that the XE900S-500 will not cause harmful interference. Labeling Requirements FCC rules require the Original Equipment Manufacturer using the XE900S-500 to place an appropriate label on the outside of the finished equipment. The label must be clearly visible and include the information shown below. Contains Transmitter Module FCC ID: DWE-XE900S-500 WARNING: This device complies with Part 15 of the FCC Rules. Its operation is subject to the following conditions: (1) This device may not cause harmful interference. (2) This device must accept any received interference including interference that may cause undesired operation. Limitations The XE900S-500 is registered under FCC Part 15 Rules. To utilize this registration on your OEM System you must follow the applications circuit provided in this data sheet and use one of the listed antennas. Any changes or modifications to the recommended circuit must be approved by Xecom. Failure to seek Xecom's approval for modifications could void certification of the end product. Warning: RF Exposure The XE900S-500 is approved for mobile, base station and mobile applications. A minimum separation of 20 centimeters should be maintained between the antenna and the equipment operator. For mobile applications check the minimum separation distances defined below. To ensure compliance, operation at distances closer than those defined is not recommended. The Warning message below must be included in the user Manual for the end product. To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20 cm separation distance between the antenna and all persons. FCC Notifications The XE900S-500 generates radio frequency energy. It must be installed according to the manufacturer's guidelines stated in the data sheet or it has the potential to cause interference with other radio devices. Testing has been performed to assure that it conforms with the FCC Part 15 rules for intentional and unintentional radiators. No further EMI compliance testing of the transmitter is required as long as the 20 cm separation and co-location requirements are observed. Each new use of the module will, however, need to be scanned for unintentional radiation from digital clocks, etc. All necessary calibration has been performed at the time of manufacture. Any modification of the device after it leaves the factory is a violation of FCC rules.
XECOM
(15)
XE900S-500
Terms of Sale
Devices sold by XECOM are covered by the warranty provisions appearing in its Terms of Sale only. XECOM makes no warranty, express, statutory, implied, or by description regarding the information set forth herein, or regarding the freedom of the described devices from patent infringement. XECOM makes no warranty of merchantability or fitness for any purposes. XECOM reserves the right to discontinue production and change specifications and prices at any time and without notice. This product is intended for use in normal commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment, are specifically not recommended without additional processing and authorization by XECOM for such application. Xecom assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xecom product. No other circuits, patents, or licenses are implied.
Life Support Policy
Xecom's products are not authorized for use as Critical Components in Life Support Devices or Systems. Life Support Devices or Systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions provided in the labeling, can be reasonably expected to result in significant injury to the user. A Critical Component is any component of a life support device or system whose failure to perform can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness.
Copyright, Xecom (c) 2005 While Xecom, Inc. has made every effort to ensure that the information presented here is accurate, Xecom will not be liable for any damages arising from errors or omission of fact. Xecom reserves the right to modify specifications and/or prices without notice. Product mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.
Xecom Incorporated 374 Turquoise Street, Milpitas, CA 95035 Ph:408-942-2200 Fax:408-942-1346 E-Mail: info@xecom.com
XECOM
(16)
XE900S-500


▲Up To Search▲   

 
Price & Availability of XE900S-500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X